logo

Philips invivo 9065/9067 Medical Battery 14.8V 97.68Wh Lithium-ion Battery Compatible with Critical Care Monitors

1
MOQ
USD
価格
Philips invivo 9065/9067 Medical Battery 14.8V 97.68Wh Lithium-ion Battery Compatible with Critical Care Monitors
特徴 ギャラリー 製品の説明 見積依頼
特徴
仕様
製品名:: 医学電池
モデル:: 989803152881
細胞タイプ:: リチウムイオンバッテリー
状態:: 新しい
電圧:: 14.8V
容量:: 6.6Ah
エネルギー:: 97.68Wh
現在:: 8.0A
ストレージライフ:: 2年半
サイクルライフ:: ≧600回
ハイライト:

14.8V Medical Battery

,

97.68Wh Lithium-ion Battery

,

Compatible with invivo 9065/9067 Monitors Medical Battery

基本情報
お支払配送条件
パッケージの詳細: カートンパッケージ
支払条件: T/T、Western Union、PayPal
製品の説明
Philips invivo 9065 989803152881 9067 Brand New Original Battery
The Philips invivo 9065/9067 Monitor Battery (REF: 989803152881) is compatible with multiple monitors including the invivo 9065 Critical Care Multi-Parameter Monitor and invivo 9067 High-End Neurocritical Care Monitor. This 14.8V, 6.6Ah battery delivers stable, long-lasting power for continuous patient monitoring in critical care environments.
Key Features
  • Long-Term Stable Power Supply: Provides 4.5-5.5 hours of continuous operation with dual battery support extending to 9-11 hours, ideal for complex monitoring and patient transport scenarios.
  • Intelligent Status Monitoring: Real-time battery life and charging progress display on monitor with low battery alerts.
  • Hot-Swap Design: Enables battery replacement without interrupting critical monitoring, essential for neurological and cardiac procedures.
Technical Specifications
Product Name Philips Battery
REF 989803174881
PN 989803152881
Battery Type Lithium-ion battery
Voltage 14.8V
Capacity 6.6Ah
Energy 97.68Wh
Condition New original
Current 8.0A
Interface Type Waterproof smart interface (with metal lock)
Storage Life 2.5 years
Cycle Life ≥600 times
Philips invivo 9065/9067 Medical Battery 14.8V 97.68Wh Lithium-ion Battery Compatible with Critical Care Monitors 0 Philips invivo 9065/9067 Medical Battery 14.8V 97.68Wh Lithium-ion Battery Compatible with Critical Care Monitors 1
Frequently Asked Questions
Q: With high-frequency EEG sampling enabled, battery life reduces to 3.5 hours instead of rated 5 hours. Is this normal?
A: Yes, this is expected due to increased power consumption from EEG sampling (approximately 3.2W). Additional monitoring functions further reduce operational time.
Q: My new battery shows "Battery Not Authenticated" when installed. What should I do?
A: First verify the security code on the battery label. If authentic, clean the metal contacts with alcohol and ensure proper connector engagement.
Q: After 4 months storage, the battery won't power the monitor. How can I activate it?
A: Charge for 2 hours to wake the lithium battery from dormancy, then calibrate and fully recharge before normal use.
推薦されたプロダクト
私達と連絡を取ってください
コンタクトパーソン : Miss. Bella Liu
電話番号 : 86 18879075074
残りの文字数(20/3000)